• Office -
    102, 1st Floor, Silver Point, Maneklal Estate, Narsi Mehta Marg, Ghatkopar W, Mumbai-400086

INFRASTRUCTURE

Sr. No.ParticularsDetails
1Land Area10,000 sq. ft.
2.Raw Material Required (Copper, Aluminum, Brass & Zinc Scrap)Approx. 55 TPM
3.Domestic Water Supply0.3 KLD
4.Blower5 HP
5.Power (DG Set)50 KVA
6.Tilting Furnace1 Ton
7.Project Cost2.7 Crores

AIR POLLUTION CONTROL SYSTEM

The system is intended for exhaust and collecting the emission in air pollution control equipment and same will be let out into atmosphere through the stacks from the ground level.

The system comprises of following units:

  1. Suction Hood
  2. Centrifugal Blower
  3. Dust Collector with Cyclone
  4. Water Scrubbing

TECHNICAL SPECIFICATION

  • Tilting Furnace – capacity 1 ton
  • Fuel – Diesel Fired
  • Air Suction pump – 10 HP
  • Hydraulic Power Pack – 5 HP
  • Oil Heating Pump – 6 Kw
  • Maximum Temperature – 1350o
  • Operating Temperature – 1160o
  • Power Supply – 440 V, 3 Phase, 50 Hz
  • Air Blower for Furnace – 5HP
  • Insulation – Graded layer insulation bricks and 70% high ALU – FIRE bricks.
  • Temperature controller – ± 5oC sensitivity